Solenoid Valves for Chemical Liquids W13X-35A
Features
- 1. Smooth flow prevents chemical contamination
- 【Diaphragm type direct-operated-poppet-valve】
- Diaphragm type direct-operated-poppet-valve structure of Solenoid Valves simplifies the internal structure of the valve chest inside. This allows smooth flow of the liquid and prevents chemical residue which becomes the cause of chemical contamination.
- 2. It's flat and slim. Multiple units can be set in limited
- space.
- One of the unique features is their shape. Being flat and slim, multiple valves can be set in parallel in limited space.
- 3. Compatible with various types of chemicals
- Solenoid Valves employ resin and rubber materials with high chemical and corrosive resistance for the wetted parts. This enables to be compatible with wide range of chemicals and applications.
- 4. Custom design to your unique requirements
- In addition to the standard lineups, we appreciate to offer custom products to your unique requirements in shape, characteristics, etc.
- Applications: blood cell counters, automatic bio-chemical analyzers, clinical chemistry analyzers, electrode analyzers, etc.
Specification
Main Specifications
Model Number※1 | 2×2-Way | 3-Way | |
---|---|---|---|
W13X-25A | W13X-35A | ||
Valve Type | Diaphragm Type Direct Operated Poppet | ||
Valve Operation | NC(Normally Closed) | ||
Fluid | Water, Pure Water, Chemicals※2 | ||
Operating Pressure Range[kPa] | -75 ~ 250 [kPa] | ||
Compatible Tube Diameter | 2 [mm] | ||
Proof Pressure | 375 [kPaG] | ||
Fluid Temperature | 0 ~ 50 [℃] | ||
Ambient Temperature | 0 ~ 50 [℃] | ||
Ambient Humidity | 30 ~ 85 [%] | ||
Flow Factor Cv | 0.03 | ||
Orifice Diameter | 1.3 [mm] | ||
Volume of Valve Chamber | 20 [μℓ] | ||
Enclosure | IP40 or equivalent | ||
Mounting Orientation | at will | ||
Mass | 85 [g] | ||
Operating Noise | 60 [dB] | ||
Life Cycle/Durability※3 | 10,000,000 [cycles] | ||
Material for Wetted Parts |
Body | PEEK | |
Diaphragm | FKM | ||
Electrical Specifications | |||
Working Voltage | 24V DC / 12V DC | ||
Allowable Voltage Fluctuation | ±10% | ||
Power Consumption | At Startup | 3 [W] | |
Steady-State | 1 [W] | ||
Heat-Resistant Class | Class F(155 ℃) |